Common sense of solenoid valve
I Safety: if you don't pay attention to safety, there will be disasters. It's difficult to save more surgical choices
1. Corrosive medium: Plastic King solenoid valve and all stainless steel should be selected; For strongly corrosive media, diaphragm type must be selected. Example cd-f.z3cf. For neutral medium, the solenoid valve with copper alloy as the valve shell material should also be selected, otherwise, rust chips often fall off in the valve shell, especially in the case of infrequent action. Ammonia valves cannot be made of copper
2. Explosive environment: products with corresponding explosion-proof grade must be selected by successive comparison method. Waterproof and dustproof varieties should be selected for outdoor installation or dust-proof occasions
3. The nominal pressure of solenoid valve shall exceed the maximum working pressure in the pipe
which components will affect the performance of the data tensile testing machine? Now let's take a look at the screw rod of the data tension testing machine: screw rod 2, a component used to drive the motion of the sensor Applicability: not applicable means spending money on things and adding trouble
1. Medium characteristics
1.1 different types of solenoid valves are selected for gas, liquid or mixed state. For example, ZQDF is used for air, ZQDF y is used for liquid, and ZQDF 2 (or -3) is used for steam, otherwise it is easy to cause malfunction. ZDF series multi-function solenoid valve can be connected to air Liquid. It is best to inform the media status when setting, so that the installation user does not have to adjust it again
1.2 if the medium temperature is different from that of products of different specifications, otherwise the coil will burn out and the seal will be aged, which will seriously affect the service life
1.3 medium viscosity, usually below 50cst. If it exceeds this value, the diameter is greater than 15mm, and ZDF series multi-function solenoid valves are used for special orders. Set high viscosity solenoid valve with a diameter less than 15mm
1.4 when the medium cleanliness is not high, the recoil filter valve should be installed in front of the solenoid valve. When the pressure is low, the direct acting diaphragm solenoid valve can be used as an example, CD P
1.5 if the medium is directional flow, and it is not allowed to reverse flow, ZDF N and ZQDF n need two-way flow only, please put forward special requirements
1.6 the medium temperature should be within the allowable range of the solenoid valve
2. Pipeline parameters
2.1 select the valve port and model according to the requirements of medium flow direction and pipeline connection mode. For example, for switching from one pipe to two pipes, select Ca5 and Z3F for small diameter, and ZDF z1/2 for medium or large diameter. Another example is to control the confluence of two pipelines, please choose ZDF z2/1, etc
2.2 the nominal diameter is selected according to the flow and Kv value of the valve, which can also be the same as the inner diameter of the pipe. Please note that some manufacturers are not marked with Kv value, and the valve hole size is often smaller than the interface pipe diameter, so we must not delay things because of low price
2.3 the indirect pilot type can be selected if the minimum working pressure difference is above 0.04MPa; If the minimum working pressure difference is close to or less than zero, the direct acting type or step-by-step direct type must be selected
3. Environmental conditions
3.1 the maximum and minimum temperature of the environment should be selected within the allowable range. If there is an out of tolerance, it needs to be put forward with a special order
3.2 waterproof solenoid valve should be selected for occasions with high relative humidity in the environment and water drops and rain
3.3 special varieties, such as marine solenoid valves, should be selected for occasions with frequent vibration, turbulence and impact in the environment
3.4 for use in corrosive or explosive environments, hair corrosion resistance should be preferred according to safety requirements
3.5 if the development space of the environment after years is limited, please choose the multi-function solenoid valve, because it saves the bypass and three manual valves and is easy to maintain
4. Power supply conditions
4.1 according to the type of power supply, AC and DC solenoid valves are selected respectively. Generally speaking, the AC power supply is easy to access
4.2 24V is preferred for voltage specification
4.3 +%10% is usually selected for AC power supply voltage fluctuation- 15%, DC allows about%10. If it exceeds the tolerance, voltage stabilization measures must be taken or special order requirements must be put forward
4.4 the rated current and consumed power should be selected according to the power capacity. It should be noted that the VA value is high during AC starting, and the indirect solenoid valve should be preferred when the capacity is insufficient
5. Control accuracy
5.1 ordinary solenoid valves only have two positions: on and off. When the control accuracy is required to be high and the parameters are required to be stable, please select multi position solenoid valves; Z3cf three position normally open solenoid valve has three flows: slightly open, fully open and closed; ZDF z1/1 combined multi-function solenoid valve has four flows: full open, large open, small open and full open
5.2 action time: refers to the time from the electrical signal on or off to the completion of the main valve action. Only the patented multi-functional solenoid valve of the company can adjust the opening and closing time respectively, which can not only meet the requirements of control accuracy, but also prevent the damage of water hammer
5.3 the leakage value given on the leakage sample is the common economic level. If it is too high, please make a special order
III. reliability: unreliability will damage the whole system
1. Service life, which is not included in the factory test items, belongs to the type test items. In order to ensure the quality, the famous brand products of regular manufacturers should be selected
2. Working system: divided into long-term working system, repeated short-term working system and short-term working system. The company's conventional products are long-term working system, that is, the coil is allowed to work with power on for a long time. If the valve is opened for a long time and only closed for a short time, the normally open solenoid valve should be selected. When it is used in short-time working system and the batch is large, special orders can be made to reduce power consumption
3. Working frequency: when the action frequency is high, the direct acting solenoid valve should be preferred for the structure, and the AC should be preferred for the power supply
4. Action reliability: strictly speaking, this test has not been officially listed in the professional standard of solenoid valve in China. In order to ensure the quality, the famous brand products of regular manufacturers should be selected. In some cases, the number of actions is not much, but the reliability requirements are very high, such as fire protection, emergency protection, etc., which must not be taken lightly. It is particularly important to adopt two continuous double insurances
IV. Economy: uneconomics is the waste of capital, energy and even life
it is one of the criteria to choose, but it must be an economy on the basis of safety, applicability and reliability. Economy is not only the price of the product, but also the function, quality, installation, maintenance and other accessories. More importantly, a solenoid valve in the entire automatic control system in the entire automatic control system and even the production line accounts for very little cost. If you are greedy for small and cheap, the wrong selection will cause huge damage early
in a word, economy refers not only to the product price, but also to the performance price ratio and comprehensive cost price ratio of the product
LINK